Issue
On Windows 11 22H2, in certain situations, closing the DataJet Server console window does not terminate the DataJet session even though the console window has been closed. Launching a new DataJet Server session re-starts the server, but performance is not as expected.
To resolve these issues, it is then necessary to:
- shut down the DataJet Server task (DJServer.exe) in windows task manager
- reopen DJServer.exe and DJExplorer.exe
This issue does not occur on Windows 10
Cause
Windows 11 22H2 released a change to the Console application.
See Link >> Windows Terminal is now the Default in Windows 11 - Windows Command Line (microsoft.com)
More info:
- Windows 10: Datajet Server is a console window event in task manager,
- Windows 11: Datajet Server is a registered exe. in the task list.
Resolution
Change default terminal settings:
- Settings > Privacy and Security > for developers > Terminal
- Set to Windows Console Host